Applied in pitched insulated roof and wall constructions as wind insulation membrane. Leave 10-15 cm overlaps, which should be fixed with Tyvek Tape or Gerband Outside DM Tape (386).
Properties:
Material: non-woven polypropylene
Weight, g/m2: 100
Windproofness (DIN 53120): Windproof
Water vapour permeability, RH=85%, 38 0C, 24 hours, g/m2: 2 665
Air layer equivalent to diffusion of water vapour Sd (DIN 52615), m: <0.01 Resistance to UV rays in months: >3
Fire resistance (EN 13501): F
Elongated tensile strength, kN/m: 157.2
Strength on tsile transverse fibres, kN/m: 226.8
Weight, g/m2: 100
Windproofness (DIN 53120): Windproof
Water vapour permeability, RH=85%, 38 0C, 24 hours, g/m2: 2 665
Air layer equivalent to diffusion of water vapour Sd (DIN 52615), m: <0.01 Resistance to UV rays in months: >3
Fire resistance (EN 13501): F
Elongated tensile strength, kN/m: 157.2
Strength on tsile transverse fibres, kN/m: 226.8
Roll parameters:
Width, cm: 150
Length, flow.m: 50
Area, m2: 75
Weight, kg: 7,9
Length, flow.m: 50
Area, m2: 75
Weight, kg: 7,9
The color tones on the screen are reproduced electronically. They may differ from the actual color tone because our color perception is affected by the surface of the material, glare, lighting, and other factors. To accurately determine a color shade, we recommend that you use real color shade catalogs, always be confident in your choice, and use the color shade catalogs in an environment or conditions similar to those for which you choose a color.